User's Manual

Using the CMC Web Interface 111
To view the health status of the temperature probes:
1
Log in to the CMC Web interface.
2
Select
Temperature Sensors
in the system tree. The
Temperature
Sensors
Information
page displays.
Table 5-6 provides descriptions of the information provided on the
Temperature Sensors Information page.
Viewing World Wide Name/Media Access
Control (WWN/MAC) IDs
The WWN/MAC Summary page allows you to view the WWN configuration
and MAC address of a slot in the chassis.
Fabric Configuration
The Fabric Configuration section displays the type of Input/Output fabric
that is installed for Fabric A, Fabric B, and Fabric C. A green check mark
indicates that the fabric is enabled for FlexAddress. The FlexAddress feature
is used to deploy chassis assigned and slot persistent WWN/MAC addresses
to various fabrics and slots within the chassis. This feature is enabled on a per
fabric and per slot basis.
Table 5-6. Temperature Sensors Health Status Information
Item Description
Present Indicates whether the sensor is present (Yes) or absent (No) in the
chassis.
Temperature ID Displays the numeric ID of the temperature probe.
Name Displays the name of each temperature probe on the chassis,
servers, IOMs, and iKVM. Examples: Ambient Temp, Server 1
Temp, I/O Module 1, iKVM Temp.
Reading Indicates the current temperature in degrees Centigrade.
Threshold
Maximum
Indicates the highest temperature, in degrees Centigrade, at which
a Failure alert is issued.
Threshold
Minimum
Indicates the lowest temperature, in degrees Centigrade, at which a
Failure alert is issued.