Table 5-24. Telnet Settings
Setting Description
Enabled Enables Telnet console interface on the CMC.
Default: Unchecked (disabled)
Max Sessions Indicates the maximum number of simultaneous Telnet
sessions allowed for the chassis. A change to this property
takes effect at the next login; it does not affect current
Active Sessions (including your own).
Allowed range: 1–4
Default: 4
NOTE: If you change the Max Sessions property to a value
less than the current number of Active Sessions and then log
out, you cannot log back in until the other sessions have been
terminated or expired.
Idle Timeout Indicates the number of seconds before an idle Telnet
session is automatically disconnected. A change to the
Timeout setting takes effect at the next login; it does not
affect the current session.
Timeout Range: 0 or 60–10800 seconds. To disable the
Timeout feature, enter 0.
Default: 1800 seconds
Port Number Indicates the port used by the CMC that listens for a server
connection.
Default: 23