User's Manual

432 Using the LCD Panel Interface
LCD Error Messages
Table C-2. CMC Status Screens
Severity Message Cause
Critical CMC <number> Battery: Battery
sensor for CMC, failed was
asserted
CMC CMOS battery is missing or
no voltage.
Critical CMC <number> CPU Temp:
Temperature sensor for CMC,
failure event
CMC CPU temperature exceeded
the critical threshold.
Critical CMC <number> Ambient Temp:
Temperature sensor for CMC,
failure event
CMC Ambient temperature
exceeded the critical threshold.
Warning Chassis FW Mismatch: Version
Change sensor for Chassis,
firmware or software
incompatibility (System BIOS in
slot XX with CMC) was asserted.
Possible loss of functionally or
features due to incompatible
software versions.
Warning Chassis FW Mismatch: Version
Change sensor for Chassis,
firmware or software
incompatibility (iDRAC in slot XX
with CMC) was asserted.
Possible loss of functionally or
features due to incompatible
software versions.
Table C-3. Enclosure/Chassis Status Screen
Severity Message Cause
Critical Chassis Fan <number> Presence:
Fan sensor for Chassis Fan, device
removed was asserted
This fan is required for proper
cooling of the enclosure/chassis.
Warning Power Supply Redundancy: PS
Redundancy sensor for Power
Supply, redundancy degraded was
asserted
One or more PSU have failed or
removed and the system can no
longer support full PSU
redundancy.