User's Manual

Using the LCD Panel Interface 433
Critical Power Supply Redundancy: PS
Redundancy sensor for Power
Supply, redundancy lost was
asserted
One or more PSU have failed or
removed and the system is no
longer redundant.
Critical Power Supply Redundancy: PS
Redundancy sensor for Power
Supply, non-redundant:
insufficient resources
One or more PSU have failed or
removed and the system lacks
sufficient power to maintain
normal operations. This could
cause servers to power down.
Critical Control Panel Temp: Temperature
sensor for Control Panel, failure
event
Chassis/Enclosure temperature
exceeded the critical threshold.
Critical CMC <number> Standalone:
Micro Controller sensor for CMC,
non-redundant was asserted
CMC no longer redundant.
NOTE: This will only show if the
standby CMC was removed or has
failed.
Critical Chassis Eventlog CEL: Event Log
sensor for Chassis Eventlog, all
event logging disabled was asserted
The CMC cannot log events.
Critical Chassis Eventlog CEL: Event Log
sensor for Chassis Eventlog, log
full was asserted
Chassis device detects that only
one entry can be added to the CEL
before it is full.
Warning Chassis Eventlog CEL: Event Log
sensor for Chassis Eventlog, log
almost full was asserted
Chassis event log is 75% full.
Table C-4. Fan Status Screens
Severity Message Cause
Critical Chassis Fan <number> Status:
Fan sensor for Chassis Fan, failure
event
The speed of the specified fan is
not sufficient to provide enough
cooling to the system.
Table C-3. Enclosure/Chassis Status Screen (continued)
Severity Message Cause