User's Manual

Using the LCD Panel Interface 435
Table C-8. Server Status Screen
Severity Message Cause
Warning System Board Ambient Temp:
Temperature sensor for System
Board, warning event
Server Ambient temperature
crossed a warning threshold.
Critical System Board Ambient Temp:
Temperature sensor for System
Board, failure event
Server Ambient temperature
crossed a failing threshold.
Critical System Board CMOS Battery:
Battery sensor for System Board,
failed was asserted
CMOS battery is not present or
has no voltage.
Warning System Board System Level:
Current sensor for System Board,
warning event
Current crossed a warning
threshold.
Critical System Board System Level:
Current sensor for System Board,
failure event
Current crossed a failing threshold.
Critical CPU <number> <voltage sensor
name>: Voltage sensor for CPU
<number>, state asserted was
asserted
Voltage out of range.
Critical System Board <voltage sensor
name>: Voltage sensor for System
Board, state asserted was asserted
Voltage out of range.
Critical CPU <number> <voltage sensor
name>: Voltage sensor for CPU
<number>, state asserted was
asserted
Voltage out of range.
Critical CPU<number> Status: Processor
sensor for CPU<number>, IERR
was asserted
CPU failure.
Critical CPU<number> Status: Processor
sensor for CPU<number>,
thermal tripped was asserted
CPU overheated.