Users Guide
chassisaction -- execute chassis or switch power-up/down/cycle or KVM powercycle
clrraclog -- clear the CMC log
clrsel -- clear the System Event Log (SEL)
cmcchangeover -- Changes the redundant state of the CMC from active to standby and vice versa
config -- modify CMC configuration properties
LEDs on a module
...
setniccfg -- modify network configuration properties
setractime -- set the time on the CMC
setslotname -- sets the name of the slot in the chassis
setsysinfo -- set the chassis name and chassis location
sslcertview -- display a CA/server certificate in the CMC
sslcsrgen -- generate a certificate CSR from the CMC
testemail -- test CMC email notifications
testtrap -- test CMC SNMP trap notifications
l racadm ? getsysinfo
getsysinfo -- display general CMC and system information
Usage:
getsysinfo [-d] [-c] [-A]
-d : show cmc information
-c : show chassis information
-A : do not show headers or labels
arp
説明
アドレス解決プロトコル(ARP)テーブルを表示します。このテーブルには IP 番号からシャーシ内の NIC の MAC アドレスへのマッピングが保存されています。
例
l racadm arp
AddressHWtypeHWaddressFlagsMaskIface
143.166.152.3ether00:07:84:A7:CE:BCCeth0
143.166.152.2ether00:07:84:7B:9F:FCCeth0
143.166.152.1ether00:00:0C:07:AC:0ACeth0
143.166.152.113 ether 00:15:C5:48:9C:1D C eth0
chassisaction
説明
シャーシ、iKVM、またはサーバーに電源処置を実行します。
使用方法
racadm chassisaction [-m <モジュール>] <処置>
オプション
表A-1 に、chassisaction サブコマンドオプションを説明します。
表 A-1.chassisactionサブコマンドオプション
メモ: このサブコマンドを使用するには、システム管理者の権限が必要です。
メモ: このサブコマンドを使用するには、シャーシ制御システム管理者の権限が必要です。
オプション
説明
-m <モジュール>
処置を実行するモジュールを指定します。<モジュール> は次のいずれかになります。
l シャーシ