Reference Guide

Example
racadm getconfig -g cfgSessionManagement cfgSsnMgtWebserverTimeout=0
cfgSsnMgtTelnetIdleTimeout=0
cfgSsnMgtSshIdleTimeout=300
cfgSsnMgtRacadmTimeout=0
cfgSsnMgtWebserverTimeout (Read/Write)
Description Defines the Web server time-out. This property sets the amount of time (in
seconds) that a connection is allowed to remain idle (there is no user input). The
session is cancelled if the time limit set by this property is reached. Changes to
this setting do not affect the current session. You must log out and log in again to
make the new settings effective.
An expired Web server session logs out the current session.
Legal Values 60 – 10800
Default 1800
cfgSerial
This group contains configuration parameters for CMC services. One instance of the group is allowed.
Use this object with the getconfig or config subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
The following sections provide information about the objects in the cfgSerial group.
NOTE: The cfgSerial object group is applicable for iDRAC Enterprise on server modules for only two properties—
cfgSerialTelnetEnable=1 and cfgSerialSshEnable=1.
cfgSerialBaudRate (Read/Write)
Description Sets the baud rate on the serial port.
Legal Values
2400, 4800, 9600, 19200, 28800, 38400, 57600,115200
Default
115200
cfgSerialConsoleEnable (Read/Write)
Description Enables or disables the RAC or CMC serial console interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
cfgSerialConsoleIdleTimeout (Read/Write)
Description
The maximum number of seconds to wait before an idle
serial session is disconnected.
Legal Values
0 = No timeout
111