Reference Guide

that of the other hosts for any kind of communication
through SNMP.
Legal Values A string representing the community name.
Default None
Example
racadm getconfig -g cfgTraps -i 2
# cfgTrapsIndex=2
cfgTrapsEnable=1
cfgTrapsAlertDestIpAddr=
cfgTrapsCommunityName=public
cfgRacTuning
This group is used to configure various iDRAC or CMC configuration properties, such as valid ports and security port
restrictions.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE: For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
Use the -m option to apply this setting to iDRAC.
The following sections provide information about the objects in the cfgRacTuning group.
cfgRacTuneDefCredentialWarningEnable
Use this object with the getconfig or config subcommands.
Description Enables or disables the display of the default password
warning message.
Legal Values
0 and 1
Default 1
cfgRacTuneRemoteRacadmEnable (Read/Write)
Description Enables or disables the Remote RACADM interface.
Legal Values
1 (TRUE)
0 (FALSE)
Default 1
cfgRacTuneHttpPort (Read/Write)
Description
Specifies the port number to use for HTTP network
communication.
Legal Values 10–65535
114