Reference Guide

cfgChassisRedundancyPolicy (Read/Write)
Description Sets the redundancy policy of the chassis.
Legal Values
0 (no redundancy)
1 (AC redundancy)
2 (power supply redundancy)
Default 0 (no redundancy)
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Description Enables or disables dynamic engagement.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisMaxPowerConservationMode (Read/Write)
Description Enables or disables maximum power conservation mode. When enabled, all servers
are immediately reduced to their minimum power levels, and all subsequent server
power allocation requests are denied. In this mode, performance of the servers that
are turned on may be degraded, and additional servers cannot be turned on,
regardless of the server priority.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisInMaxPowerCapacity (Read Only)
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Description Indicates the amount of redundant power (in Watt) in reserve that can be utilized in
the event of an AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to
0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
138