Reference Guide

Turn off server 3 from iDRAC
racadm serveraction powerdown
Server power operation successful
Turn off server 3 from CMC when Power is already Off on that server
racadm serveraction -m server-3 powerdown
Server is already powered OFF.
Turn off the server from iDRAC when Power is already off on that server.
racadm serveraction powerdown
Server is already powered OFF
Get Power Status of server 2 on CMC
racadm serveraction -m server-2 powerstatus
ON
Get Power Status on iDRAC
racadm serveraction powerstatus
Server Power Status: ON
Reseat server 2 on CMC
$ racadm serveraction -m server-2 reseat -f
Server power operation successful
Explanation of Support
iDRAC needs to support graceful shutdown
The support of address individual blades is expected on the CMC
set
Description
Imports the saved CMC Event Filter configuration from a file.
NOTE: Currently, these commands are supported only in remote RACADM.
Synopsis
racadm set -f <filename>
Input
–f: Configure event filter configurations from a configuration file.
Example
–Configure event filter configurations from a configuration file.
racadm -r 10.94.161.119 -u root -p calvin set -f
config.txt
setassettag
Description Sets the N-byte ASCII asset tag for the chassis.
To use this subcommand, you must have the Administrator privilege.
Synopsis
racadm setassettag -m chassis <asset tag>
Input -m <
module
> — Specifies the module whose asset tag you want to set.
Legal value: chassis