Quick Reference Guide

-v — The -v option displays additional details with the
display of the properties and is used with the -g
option.
Output This subcommand generates error output upon
encountering either of the following:
Invalid syntax, group name, object name, index, or
other invalid database members
RACADM CLI transport failures
If errors are not encountered, this subcommand displays
the contents of the specified configuration.
Example
Displays all of the configuration properties (objects)
that are contained in the group cfgLanNetworking.
racadm getconfig -g cfgLanNetworking
Saves all group configuration objects from iDRAC to
myrac.cfg.
racadm getconfig -f myrac.cfg
Displays a list of the available configuration groups on
iDRAC in an alphabetical order.
racadm getconfig -h
Displays the configuration properties for the user
named root.
racadm getconfig -u root
Displays the user group instance at index 2 with
verbose information for the property values.
racadm getconfig -g cfgUserAdmin -i
2 -v
getdcinfo
Description Displays general I/O module and daughter card configuration information. Only the
CMC controls daughtercards.
To use this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the chassis is
turned on. When the chassis is on stand-by power, iDRACs on the server
modules remain turned off and thus are unable to report the server's DC fabric
type. The DC fabric type may not be reported in the CMC user interface until
iDRAC on the server is turned on.
Synopsis
racadm getdcinfo
Input -n — Displays the model names for the daughter cards in servers.
Example
36