User's Manual

NOTE: To apply chassis events configuration changes, you must have the Alert Configuration
privilege.
1. In the left pane, click Chassis Overview Alerts.
2. On the Chassis Events page, under the Alerts Filter section, select one or more of the following
categories:
System Health
Storage
Configuration
Audit
Updates
3. Select one or more of the following severity levels:
Critical
Warning
Informational
The Monitored Alerts section displays the results based on the selected category and severity. For
information about the field descriptions on the this page, see the Online Help.
4. Click Apply.
Setting Event Alerts Using RACADM
To set an event alert, run the eventfilters command. For more information, see the Chassis
Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide
available at
dell.com/support//manuals.
Configuring Alert Destinations
The management station uses Simple Network Management Protocol (SNMP) to receive data from CMC.
You can configure the IPv4 and IPv6 alert destinations, email settings, and SMTP server settings, and test
these settings.
Before configuring the email alert or SNMP trap settings, make sure that you have the Chassis
Configuration Administrator privilege.
Configuring SNMP Trap Alert Destinations
You can configure the IPv6 or IPv4 addresses to receive the SNMP traps.
104