Reference Guide
– powerdown — (Chassis only) Turns off the
chassis.
– powerup — (Chassis only) Turns on the chassis.
– powercycle — Power cycles the module.
– nongraceshutdown — (Chassis only) Non-
gracefully turns off the chassis.
– reset — Performs a hard reset of the module.
When <
module
> = switch, <
action
> must be powercycle
or reset.
Output None
Example Perform a reset of switch-1:
racadm chassisaction -m switch-1 reset
Module power operation successful.
closessn
Description Closes a communication session on the device. Use the
getssninfo command to view a list of sessions that
can be closed using this command.
To use this subcommand, you must have the Administrator
privilege.
Synopsis
• racadm closessn –i <session id>
• racadm closessn -a
• racadm closessn -u <username>
Input
• -i<
session id
> — The session ID of the session to be
ended, which can be retrieved using RACADM
getssninfo subcommand.
Session executing this command cannot be ended.
• -a — Closes all sessions.
• -u
<user name>
— Close all sessions for a particular
user name.
– Remote RACADM: -u option or -i option
Output None
Example
• racadm closessn -i 1234
Closes the session 1234.
• racadm closessn –u root
Closes all the sessions for root user.
• racadm closessn –a
Closes all the sessions.
23