Reference Guide

Fan-4 OK 4045 840 600 N/A N/A
Fan-5 OK 4107 840 600 N/A N/A
Fan-6 OK 0 840 600 N/A N/A
Blower-1 N/A 0 3000 2250 N/A N/A
Blower-2 N/A 0 3000 2250 N/A N/A
Blower-3 N/A 0 3000 2250 N/A N/A
Blower-4 N/A 2611 3000 2250 N/A N/A
Sensor Type : Temperature
Sensor Units : Celsius
<Sensor
Name>
<Statu
s>
<Readin
g>
<LW> <LC> <UW> <UC>
Chassis
Ambient
OK 22 3 -7 42 47
Server-4 OK 20 3 -7 42 47
Sensor Type : Power
<Sensor Name> <Status> <AC-OK status>
PS-1 Slot Empty N/A
PS-2 Online OK
PS-3 Slot Empty N/A
PS-4 Slot Empty N/A
Sensor Type : Cable
<Sensor Name> <Status>
IO-Cable OK
FPC-Cable OK
Sensor Type : Intrusion
<Sensor Name> <Intrusion>
Chassis Intrusion Closed
getslotname
Description
Displays the name and host name (if available) of all the four slots, or of a specified slot
(indicated by the slot number) in the chassis. Optionally, use this command to find if the slot
name or host name is displayed in the CMC Web interface, or with the getslotname [-i
<
slotNum
> | -h] command. If the host name is not available, the static slot name is used.
To use this subcommand, you must have CMC Login User privilege.
Synopsis
racadm getslotname
racadm getslotname [-i <
slotNum
> | -h]
racadm getslotname -h
Input
None -
Displays the slot name for all the four slots in the chassis.
51