Reference Guide

getsvctag
Description Displays the service tag of the host system.
Synopsis
racadm getsvctag
Input
getsvctag
Output
<Module> <ServiceTag>
Chassis PLPC033
Switch-1 N/A
Server-1 7654321
Server-2 N/A
Server-3 Extension(1)
Server-4 PLSMS04
Example
racadm getsvctag
getsysinfo
Description
Displays information related to CMC and chassis.
NOTE: The Hostname and OS Name fields in the getsysinfo output display accurate information
only if Dell OpenManage Server Administrator is installed on the managed system. Else, these
fields may be blank or inaccurate. An exception to this are VMware operating system names,
which are displayed even if Server Administrator is not installed on the managed system.
Synopsis
racadm getsysinfo [-d] [-c] [-A] [-4] [-6]
Input
-d - Displays CMC information.
-c - Displays chassis information.
-A - Does not display headers and labels.
-4 - Displays IPv4 information.
-6 - Displays IPv6 information.
Output
CMC Information:
CMC Date/Time = Sat Mar 27 1982 11:36
Primary CMC Location = CMC-1
Primary CMC Version = 1.00
Standby CMC Version = N/A
Last Firmware Update = Sun Mar 21 1982 05:53
Hardware Version = X12
CMC Network Information:
NIC Enabled = 1
MAC Address = 78:45:C4:F7:8B:29
Register DNS CMC Name = 1
DNS CMC Name = cmc-servicetag
Current DNS Domain = swtest.com
VLAN ID = 1
VLAN Priority = 0
VLAN Enabled = 0
CMC IPv4 Information:
IPv4 Enabled = 1
53