Reference Guide

racadm raid get vdisks -o -p layout,status
racadm raid get controllers:RAID.ChassisIntegrated.1-1
racadm raid get controllers:RAID.ChassisIntegrated.1-1 -p
status
racadm raid resetconfig:RAID.ChassisIntegrated.1-1
racadm raid exportlog:RAID.ChassisIntegrated.1-1 -l <CIFS
or NFS share> -u <user name> -p <password> [-f <filename>]
racadm raid forceonline:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
racadm raid deletevd:Disk.Virtual.0:RAID.ChassisIntegrated.
1-1
racadm raid blink:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
racadm raid clearconfig:RAID.ChassisIntegrated.1-1
racadm raid importconfig:RAID.ChassisIntegrated.1-1
racadm raid ccheck:Disk.Virtual.0:RAID.ChassisIntegrated.
1-1
racadm raid cancelcheck:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 {-pdkey:<comma separated PD
FQDDs> | {-vdkey:<comma separated VD FQDDs>}
racadm raid unblink {-pdkey:<comma separated PD FQDDs> | -
vdkey:<comma separated VD FQDDs>}
racadm raid patrolread:RAID.ChassisIntegrated.1-1 [-mode
{auto | manual | disabled}] [-state {start | stop}] racadm
raid hotspare:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1 -assign {yes | no} -type
{ ghs | dhs} -vdkey:<FQDD of VD>
racadm raid init:Disk.Virtual.0:RAID.ChassisIntegrated.1-1
-speed { fast | full } racadm raid cancelinit:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 racadm raid assignva:<VA FQDD>
-vdkey:<FQDD of VD> -accesspolicy { na | rw }
racadm raid createvd:RAID.ChassisIntegrated.1-1 -rl {r0|r1|
r5|r6|r10|r50|r60} [-wp {wt|wb}] [-rp {nra|ra|ara}] [-ss
{1k|2k|4k|8k|16k|32k|64k|128k|256k|512k|1M|2M|4M|8M|16M}] -
pdkey:<comma separated PD FQDDs>
[-dcp {enabled|disabled|default}] [-name <VD name>] [-size
<VD size> {b|k|m|g|t}] [-cc]
racadm raid discardcache:RAID.ChassisIntegrated.1-1
racadm raid changepolicy:Disk.Virtual.
0:RAID.ChassisIntegrated.1-1 -wp {wt|wb} -rp {nra|ra|ara} -
dcp {enabled|disabled|default} racadm raid
rename:Disk.Virtual.0:RAID.ChassisIntegrated.1-1 -name <VD
name>
racadm raid ctrlprop:RAID.ChassisIntegrated.1-1 [-rebuild
<value>>] [-bgi <value>] [-reconstruct <value>] [-
checkconsistency <value>] [-ccmode {abortonerror | normal}]
[-copybackmode {off | on | onwithsmart}] [-lb {auto |
disabled}] [-prunconfigured {yes | no}] racadm raid
rebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1 racadm raid
cancelrebuild:Disk.Bay.0:Enclosure.Internal.
0-0:RAID.ChassisIntegrated.1-1
raid
Description
Allows you to execute commands to control RAID arrays.
76