Reference Guide
To use this subcommand for CMC you must have Chassis Administartor privilege.
Synopsis
racadm raid
Example
• Monitor Health of Storage root node
racadm raid get status
Storage Root Node Status : Ok
This command retrieves the controllers keys, (FQDDs.)
• Monitor and Inventory all Controllers connected to the server
racadm raid get controllers
racadm raid get controllers -o
This command is an optimized version and displays the full controller objects along with their keys.
racadm raid get controllers -o -p <property names separated by comma>
This command displays the filtered property values for all returned controller objects.
• Monitor and Inventory all batteries connected to the controller
racadm raid get batteries --refkey <controller FQDDs
separated by comma
>
This command displays all battery keys connected to the controllers referred to as refkeys.
racadm raid get batteries --refkey <controller FQDDs
separated by comma > -o
This command is an optimized version and displays all battery objects for the controller FQDD.
racadm raid get batteries --refkey <controller FQDDs
separated by comma
> -o -p <property names separated by comma>
This command is an optimized and filtered version.
racadm raid get batteries --refkey <controller FQDDs
separated by comma > -o -p <property names separated by comma>
• Monitor and Inventory all virtual disks connected to the controller
racadm raid get vdisks --refkey <controller FQDDs
separated by comma>
This command displays all vdisk keys connected to the controllers being mentioned as refkeys.
racadm raid get vdisks --refkey <controller FQDDs
separated by comma
> -o
This command is an optimized version and displays all vdisk objects for the controller FQDD.
racadm raid get <controller > -pending
Raid.Integrated.1-1
Raid.Slot.2-1
• Monitor and Inventory all storage enclosures connected to the connector
racadm raid get enclosures --refkey <connector FQDDs
separated by comma>
This command displays all enclosure keys connected to the connectors being mentioned as refkeys.
racadm raid get enclosures --refkey <connector FQDDs
separated by comma > -o optimized version.
77