Users Guide

Enabling or Disabling RAID Controller Using CMC Web
Interface
For a VRTX chassis with two Shared PERC8 controllers, the Integrated 2 PERC adapter can be disabled or
enabled when the Integrated 1 PERC adapter is active and all server modules are turned off. Both
adapters must be enabled for fault-tolerance. The
Controllers Troubleshooting page allows you to
enable or disable the peer controller.
NOTE: To prevent loss of data, before performing controller enable or disable operations:
Complete all data operations such as Rebuild or Copy Back.
Make sure that the data volumes are in optimal state.
NOTE: While enabling the second PERC adapter, a warning message is displayed and the fault-
tolerant status is degraded if:
Any of the PERC adapter settings are changed.
Firmware is updated.
Make sure that the firmware and the settings of the shared PERC match to set the fault tolerant
system configuration to Fault Tolerant mode.
You can disable a peer controller only if:
All the servers in the chassis are turned off.
The Integrated 1 PERC is currently the active controller.
NOTE: If the Integrated 1 PERC is not currently the active controller, then perform a chassis
power cycle to make this the active controller.
Both CMCs have the same firmware version that supports this feature.
NOTE: After disabling Integrated 2 PERC , to replace a CMC card, it is recommended to update the
CMC card with firmware version 1.35 or later, before the card is assigned to be the active CMC
controller in the system. A message is displayed before you perform this action.
To enable or disable a peer controller in fault-tolerant mode using the CMC Web interface:
1. In the left pane, click Chassis Overview Storage Controllers Troubleshooting.
2. On the Controller Troubleshooting page, from the Actionsdrop-down menu for Integrated 2 PERC,
select one of the following, and then click Apply.
Disable RAID Controller — Disables the peer controller in fault-tolerant mode. This option is
available in the drop-down menu only for the Integrated 2 PERC when it is not disabled.
Enable RAID Controller — Enables the peer controller in fault-tolerant mode. If the Integrated 2
PERC is already disabled, then the Enable Raid Controller option is available in the drop-down
menu.
NOTE:
For a disabled PERC, none of the other options Reset Configuration, Export TTY Log, Discard
Pinned Cache, and Disable RAID Controller are available in the drop-down menu.
NOTE: Enabling or disabling a peer controller initiates a chassis power cycle. The changes are
reflected only after the power cycle is complete.
186