Connectivity Guide

TrapID Description Severity
527106 Power Supply Redundancy Degraded Warning
527105 Power Supply Redundancy Lost Critical
527104 Power Supply Redundancy has returned
to Normal
Information
552704 Power Supply Inserted Information
552832 Power Supply Removed Warning
552705 Power Supply Failure Critical
552833 Power Supply Failure Cleared Information
552706 Power Supply Warning Warning
552834 Power Supply Warning Cleared Information
552707 Power Supply AC Lost Critical
552835 Power Supply AC Restored Information
789249 Memory Redundancy has been Lost Critical
789248 Memory redundancy has returned to
Normal
Information
1076994 System Event Log (SEL) Cleared Information
1076996 System Event Log (SEL) Full (Logging
Disabled)
Critical
2322176 ASR (Automatic System Recovery) Timer
Expired
Critical
2322177 ASR (Automatic System Recovery) Reset
Occurred
Critical
2322178 ASR (Automatic System Recovery) Power
Down Occurred
Critical
2322179 ASR (Automatic System Recovery) Power
Cycle Occurred
Critical
PowerEdge M1000e CMC Traps
This section describes the traps that are generated by the SNMP agent of the PowerEdge M1000e CMC. All of the enterprise-
specic traps documented in this section belong to the MIB enterprise identied by OID 1.3.6.1.4.1.674.10892.2 and are sent with the
following trap variables: drsProductChassisName, drsProductChassisLocation, drsGlobalCurrStatus, drsCASubSystem,
drsCASSCurrStatus, drsCASSPrevStatus, drsCASSChangeTime and drsCAMessage.
PowerEdge M1000e CMC version 5.0 and later supports a setting to generate the traps listed in the section "PowerEdge VRTX
CMC Traps and PowerEdge FX2 CMC Traps". The setting is named "Enable Enhanced Chassis Logging and Events" in the
PowerEdge M1000e CMC GUI and is located in the General Chassis Settings page which can be found by navigating to Chassis
Overview -> Setup -> General in the CMC GUI. When the setting is disabled, the traps listed in this section are generated by the
CMC. When the setting is enabled, the traps listed in the section "PowerEdge VRTX CMC Traps and PowerEdge FX2 CMC Traps"
are generated by the CMC instead of the traps listed in this section. The setting is disabled by default. The trap variables are dened
in the Dell Remote Access Controller Out-of-Band Group section.
35