Connectivity Guide

Access read-only
Enclosure Temperature Probe Table
The objects provide information about the Enclosure Temperature Probe Table group in storage.
NOTE: The Storage Details Group is introduced in VRTX CMC from this release. The iDRAC and CMC have the same
Storage attributes with some modication in CMC. The Object ID mentioned example:
1.3.6.1.4.1.674.10892.
5.5
.1.20.130.11.1.1 for the table group are attributes for checking on iDRAC. To check the
corresponding set of attributes for VRTX CMC systems, use the Object ID example:
1.3.6.1.4.1.674.10892.
2.6
.1.20.130.11.1.1.
Table 354. Enclosure Temperature Probe Number
Name
enclosureTemperatureProbeNumber
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.1
Description Instance number of this temperature probe
Syntax INTEGER (1..255)
Access read-only
Table 355. Enclosure Temperature Probe Name
Name
enclosureTemperatureProbeName
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.2
Description The temperature probe's name as represented in Storage Management
Syntax DisplayString
Access read-only
Table 356. Enclosure Temperature Probe State
Name
enclosureTemperatureProbeState
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.4
Description The current state of this temperature probe. Possible states:
1. The current state could not be determined
2. The temperature probe is operating normally
3. The temperature probe has encountered a hardware problem or is not
responding
4. The temperature probe is no longer connected to the enclosure or there
exists a problem communicating to it
5. The temperature probe is unstable
6. The temperature probe is Over Warning Temperature
7. The temperature probe is Under Warning Temperature
Syntax INTEGER
Access read-only
Table 357. Enclosure Temperature Probe Min Warning Value
Name
enclosureTemperatureProbeMinWarningValue
Object Id 1.3.6.1.4.1.674.10892.5.5.1.20.130.11.1.7
Description The minimum temperature that will force the probe into a warning state.
90