cfgChassisMaxPowerConservationMode (Read/Write)
Description Enables or disables maximum power conservation mode. When enabled, all servers are
immediately reduced to their minimum power levels, and all subsequent server power allocation
requests are denied. In this mode, performance of the servers that are turned on may be
degraded, and additional servers cannot be turned on, regardless of the server priority.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisPowerCapUpperBound (Read Only)
Description Indicates the minimum chassis thermal capacity, power supply capacity, and server maximum
input.
Legal Values
Default
cfgChassisPowerCapLowerBound (Read Only)
Description
Indicates the minimum power required to operate the chassis with the servers running.
Legal Values
Default
cfgChassisSledPowerButtonEnable
Description
Permits to use the power button on all multi-node Sleds (such as the FM120).
Legal Values
1 — Enable
0 — Disable
Default 1
cfgChassisPowerCap (Read/Write)
Description
Indicates the maximum power consumption limit (in Watts) for the entire chassis. The command
generates an error if server throttling is necessary to achieve the power goal based on the value
for this setting.
Legal Values 539 – 3371 Watts
Default 3371 Watts