cfgChassisPowerButtonEnable (Read/Write)
Description Indicates if the chassis power button is enabled or disabled.
Legal Values
0 (disabled)
1 (enabled)
Default None
cfgChassisPowerCapBTU (Read/Write)
Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command
generates an error if server throttling is necessary to achieve the power goal based on the value
for this setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
cfgChassisACPowerRecoveryDisable
Description
If AC power recovery is disabled, the chassis is powered o after power outage is restored.
Legal Values
0 — Enable
1 — Disable
Default
0
cfgKVMInfo
This group is used to view the mapping information for the KVM.
Use this object with the cong or getcong subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
cfgKvmEnable
Description
Enable KVM operation for all slots
Legal Values
0 — Disable
1 — Enable
Default 1
cfgKvmMapping
Description
Selects the server to which the KVM connects
Legal Values
1[a-d]-4[a-d]
128