Reference Guide
idRacVersionInfo (Read Only)
Description String containing the current product rmware version.
Legal Values A string of up to 63 ASCII characters.
Default The current version number.
idRacBuildInfo (Read Only)
Description String containing the current RAC rmware build version.
Legal Values A string of up to 16 ASCII characters.
Default for CMC The current CMC rmware build version.
idRacName (Read Only)
Description A user-assigned name to identify this controller.
Legal Values A string of up to 15 ASCII characters.
Default for CMC CMC
cfgLanNetworking
This group contains parameters to congure CMC NIC for IPv4.
One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using
the updated IP address settings.
For CMC, use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have the Chassis Conguration Administrator privilege.
NOTE: For CMC, you can congure a setting that does not have a hash sign (#) prexed in the output. To modify a
congurable object, use the –o option.
The following sections provide information about the objects in the cfgLanNetworking group.
cfgNicIPv4Enable (Read or Write)
Description
Enables or disables the IPv4 stack.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default
• For iDRAC: 0
• For CMC: 1
89