Users Guide

Table Of Contents
To enable the maximum power consumption mode, type:
racadm config -g cfgChassisPower -o
cfgChassisMaxPowerConservationMode 1
To restore normal operation, type:
racadm config -g cfgChassisPower -o
cfgChassisMaxPowerConservationMode 0
To enable the power remote logging feature, enter the following command:
racadm config -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingEnabled 1
To specify the desired logging interval, enter the following command:
racadm config -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingInterval n
where n is 1-1440 minutes.
To determine if the power remote logging feature is enabled, enter the following command:
racadm getconfig -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingEnabled
To determine the power remote logging interval, enter the following command:
racadm getconfig -g cfgRemoteHosts -o
cfgRhostsSyslogPowerLoggingInterval
The power remote logging feature is dependent on previously configured remote syslog hosts having been . Logging to
one or more remote syslog hosts must be enabled, otherwise power consumption is logged. This can be done either
through the web GUI or the RACADM CLI. For more information, see the remote syslog configuration instructions.
To restore CMC power management, type:
racadm config -g cfgChassisPower -o
cfgChassisServerBasedPowerMgmtMode 0
For information about RACADM commands for chassis power, see the config, getconfig, getpbinfo, and
cfgChassisPower sections in the Dell Chassis Management Controller for PowerEdge FX2/FX2s RACADM Command Line
Reference Guide.
Executing Power Control Operations
You can execute the following power control operation for the chassis, servers, and IOM.
NOTE: Power control operations affect the entire chassis.
Executing Power Control Operations on the Chassis
CMC enables you to remotely perform several power management actions, such as an orderly shutdown on the entire chassis
(chassis, servers, IOM, and PSUs).
Executing Power Control Operations on the Chassis Using Web Interface
To execute power control operations on the chassis using the CMC web interface:
1. In the left pane, click Chassis Overview > Power > Control.
The Chassis Power Control page is displayed.
2. Select one of the following power control operations.
For information about each option, see the Online Help.
Power On System
140
Managing and monitoring power