CLI Guide

getexaddr
Description Displays enabled or disabled status for the entire chassis. If used with -i, the command displays
MACs/WWN on a per-slot–basis.
The decoder values in the Type column indicate the protocols of the network cards:
0— Unsupported
1— ISCSI
2— FCoE-FIP
3— iSCSI/FCoE-FIP
To use this subcommand, you must have CMC Login User privilege.
NOTE: If FlexAddress is not activated on the chassis, the command displays server-
assigned MAC/WWN addresses. If the slot is empty, the command leaves the server-
assigned MAC/WWN addresses blank. If an external console controls the MAC/WWN
addresses, the command displays an externally managed message.
Synopsis
racadm getflexaddr [-i <slotNum>]
Input -i < slotNum > — Species the slot information to be displayed. < slotNum > must be from 1 to 4.
Example
Display current FlexAddress settings for all the slots and fabrics.
racadm getflexaddr
<Slot#> <Status> <Server Presence>
1a Enabled Present
1b Enabled Present
1c Enabled Present
1d Enabled Not Present
2 Enabled Present
3a Disabled Present
3b Disabled Present
3c Disabled Present
3d Disabled Present
4 Disabled Present
idrac System Disabled
Display the current FlexAddress setting for slot 1.
racadm getflexaddr -i 1
Slot-1 server presence = Present
Slot-1 flexaddress enabled = 1
36