CLI Guide

CMC-n , where n = 1
fan-n , where n = 1 to 8
ps-n , where n = 1 to 2
chassis
main-board
io-cable
fpc cable
-A — Does not display the headers and labels in the output.
Example
racadm getmodinfo -m switch-1
<module> <presence> <pwrState> <health> <svcTag> Switch-1 Present ON OK CG09074
racadm getmodinfo
<module> <presence> <pwrState> <health> <svcTag> <node Id>
Chassis
Present ON OK ST0MP19 N/A
Main-Board Present ON OK N/A N/A
Storage-2
Present OFF Not OK 6666666 N/A
Storage-3 Present OFF Not OK 6666666 N/A
Storage-4 Present OFF OK 6666666 N/A
Fan-1 Present ON OK N/A N/A
Fan-2 Present ON Unknown N/A N/A
Fan-3 Present ON Unknown N/A N/A
Fan-4 Present ON Unknown N/A N/A
Fan-5 Present ON OK N/A N/A
Fan-6 Present ON Unknown N/A N/A
Fan-7 Present ON Unknown N/A N/A
Fan-8 Present ON Unknown N/A N/A
PS-1 Present Online OK N/A N/A
PS-2 Present Online OK N/A N/A
CMC Present Primary OK N/A N/A
Switch-1 Present ON OK 0000000 N/A
Switch-2 Present ON OK N/A N/A
Server-1 Present OFF OK H23H23Z H23H23Z
Server-2a Present OFF OK JD3FRTW JD3FRTWa
Server-2b Present OFF OK JD3FRTW JD3FRTWb
Server-2c Present OFF OK JD3FRTW JD3FRTWc
44 RACADM Subcommand Details