Release Notes
Known Issues
• Issue 1:
Description
PCIe card device name displayed on the iDRAC GUI and CMC GUI are not same for Broadcom/Qlogic 10G card.
Resolution
Refer to the iDRAC GUI, it is accurate and current.
Versions/Systems Aected
None
• Issue 2:
Description
An error occurs while importing CMC conguration le using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the command, racadm
config -g cfgIPv6LanNetworking -o cfgIPv6Enable 0
.
Versions/Systems Aected
CMC for PowerEdge FX2 1.10 or later
• Issue 3:
Description
MCM Inventory report has limited RAID and NIC details. There is a dierence in the RAID and NIC inventory details on the Server
Component Update page and the MCM inventory report.
Resolution
In the CMC GUI, refer to the Server Overview -> Update -> Server Component Update page, it is accurate and current.
Versions/Systems Aected
All CMC versions including CMC 2.00 for Dell EMC PowerEdge FX2/FX2s.
• Issue 4:
Description
The value of "Power Available for Server Power-on” can increase after PSU failure and recovery, without any changes to the underlying
chassis hardware components.
Resolution
For actual power consumption of the chassis, in the CMC GUI, navigate to the Chassis Overview > Power > Power Monitoring >
System Input Power page.
Versions/Systems Aected
8
12 Known Issues