Quick Reference Guide

142 Using the LCD Panel Interface
Table 4-5. IOM Status Screens
Severity Message Cause
Warning I/O Module <number> Status:
Module sensor for I/O Module,
transition to non-critical from OK
was asserted
The IO module was good, but now
having fabric mismatch or link
tuning mismatch.
Critical I/O Module <number> Status:
Module sensor for I/O Module,
transition to critical from less
severe was asserted
The I/O module has a fault. The
same error can also happen if the
I/O module is thermal-tripped.
Table 4-6. iKVM Status Screen
Severity Message Cause
Warning Local KVM Health: Module sensor
for Local KVM, transition to non-
critical from OK was asserted
Minor failure, such as corrupted
firmware.
Critical Local KVM Health: Module sensor
for Local KVM, transition to
critical from less severe was
asserted
USB host enumeration failure or
OSCAR failure.
Non-
Recoverable
Local KVM Health: Module sensor
for Local KVM, transition to non-
recoverable was asserted
Serial RIP failure or USB host chip
failure.
Table 4-7. PSU Status Screens
Severity Message Cause
Critical Power Supply PSU <number>:
Power Supply sensor for Power
Supply, failure was asserted
The PSU has failed.
Critical Power Supply PSU <number>:
Power Supply sensor for Power
Supply, input lost was asserted
Loss of AC power or AC cord
unplugged.