Quick Reference Guide

Using the LCD Panel Interface 151
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front
panel LCD for each type of component in the chassis.
Critical LinkT/ FlexAddr: Link Tuning
sensor, device option ROM failed
to support link tuning or flex
address (Mezz XX) was asserted
PCI device Option ROM for a NIC
does not support link tuning or the
FlexAddress feature.
Critical LinkT/ FlexAddr: Link Tuning
sensor, failed to program virtual
MAC address (<location>) was
asserted
BIOS failed to program virtual
MAC address on the given NIC
device.
Critical I/O Fatal Err: Fatal IO Group
sensor, fatal IO error (<location>)
Generated in association with a
CPU IERR and indicates which
device caused the CPU IERR.
Warning PCIE NonFatal Er: Non Fatal IO
Group sensor, PCIe error
(<location>)
Generated in association with a
CPU IERR.
Table 4-9. CMC Status
Item Description
Name/Location Example: CMC1, CMC2
Error Messages If no error then "No Errors" is shown; otherwise error messages
are listed, critical errors first, then warnings.
IP Address Only shows on active CMC.
Firmware Version Only shows on active CMC.
Table 4-10. Chassis/Enclosure Status
Item Description
User Define Name Example: “Dell Rack System”. This is settable via CMC CLI
or Web GUI
Table 4-8. Server Status Screen (continued)
Severity Message Cause