Quick Reference Guide

52 RACADM Subcommands
ERROR: Server in slot 9 is an extension of the
server in slot 1.
getpbinfo
NOTE: To use this subcommand, you must have CMC Login User privilege.
Description
Displays power budget status information.
Usage
racadm getpbinfo
Example
racadm getpbinfo
[Power Budget Status]
System Input Power = 700 W
Peak System Power = 0 W
Peak System Power Timestamp = 01:08:23 01/27/2009
Minimum System Power = 0 W
Minimum System Power Timestamp = 20:18:30 01/27/2000
Overall Power Health = Not OK
Redundancy = No
System Input Power Cap = 7928 W
Redundancy Policy = None
Dynamic PSU Engagement Enabled = No
System Input Max Power Capacity = 0 W
Input Redundancy Reserve = 0 W
Input Power Allocated to Servers = 0 W
Input Power Allocated to Chassis Infrastructure =
51 watts
Total Input Power Available for Allocation = 0 W
Standby Input Power Capacity = 0 W