Quick Reference Guide

76 RACADM Subcommands
Example
racadm serveraction -m server-1 powerup
Server power operation successful.
racadm serveraction -m server-9 powerup
ERROR: Server in slot 9 is an extension of the
server in slot 1.
setchassisname
NOTE: To use this subcommand, you must have Administrator privilege.
Description
Sets the name of the chassis in the LCD.
Usage
racadm setchassisname <name>
Table 2-29. serveraction Subcommand Options
Option Description
-m server-n Specifies the server by its slot number (1–16) in the chassis.
For example, server-2.
-a The specified power action is performed on all servers
<action> Specifies the action. <action> may be one of the following:
powerdown
— Powers down the server.
powerup
— Powers up the server.
powercycle
— Issues a power-cycle operation on the
server.
hardreset
— Performs a reset (reboot) operation on the
server.
graceshutdown
— Shuts down the server gracefully.
powerstatus
— Displays current power status (Online,
Off) of the server.