User's Manual

140 Using the CMC Web Interface
4
Configure the following services as required:
CMC serial console (Table 5-21)
Web server (Table 5-22)
SSH (Table 5-23)
Telnet (Table 5-24)
Remote RACADM (Table 5-25)
5
Click
Apply;
update all default time outs and maximum time out limits.
Table 5-21. CMC Serial Console Settings
Setting Description
Enabled Enables Telnet console interface on the CMC.
Default: Unchecked (disabled)
Redirect Enabled Enables the serial/text console redirection to the server
through your serial/Telnet/SSH client from the CMC. The
CMC connects to iDRAC that internally connects to the
server COM2 port.
Configuration options: Checked (enabled), unchecked
(disabled)
Default: Checked (enabled)
Idle Timeout Indicates the number of seconds before an idle serial
session is automatically disconnected. A change to the
Timeout setting takes effect at the next login; it does not
affect the current session.
Timeout Range: 0 or 60 to 10800 seconds. To disable the
Timeout feature, enter 0.
Default: 1800 seconds
Baud Rate Indicates the data speed on the external serial port on the
CMC.
Configuration options: 9600, 19200, 28800, 38400, 57600,
and 115200 bps.
Default: 115200 bps
Authentication
Disabled
Enables CMC Serial Console login authentication.
Default: Unchecked (disabled)