User's Manual

178 Using FlexAddress
For further information on the command, see the feature command section
of the Dell Chassis Management Controller Firmware Version 2.0
Administrator Reference Guide.
Viewing FlexAddress Status Using the CLI
You can use the command line interface to view FlexAddress status
information. You can view status information for the entire chassis or for a
particular slot. The information displayed includes:
Fabric configuration
FlexAddress enabled/disabled
Slot number and name
Chassis-assigned and server-assigned addresses
Addresses in use
Use the following RACADM command to display FlexAddress status for the
entire chassis:
racadm getflexaddr
To display FlexAddress status for a particular slot:
racadm getflexaddr [-i <slot#>]
<slot#> = 1 to 16
Refer to "Configuring FlexAddress" for additional details on FlexAddress
configuration. For additional information on the command, see the
getflexaddr command section of the Dell Chassis Management Controller
Firmware Version 2.0 Administrator Reference Guide.
Configuring FlexAddress Using the CLI
You can use the command line interface to enable or disable FlexAddress on a
per fabric basis. Additionally, you can enable/disable the feature on a per slot
basis. After you enable the feature on a per-fabric basis, you can then select
slots to be enabled. For example, if Fabric-A is enabled, any slots that are
enabled will have FlexAddress enabled only on Fabric-A. All other fabrics will
use the factory-assigned WWN/MAC on the server.