User's Manual

234 Power Management
Amber - PSU is present, but may or may not be powered on, or may or
may not be communicating with the CMC; an adverse condition may
exist.
Gray - PSU is present and not powered on. It is not communicating
with the CMC and there is no indication of an adverse condition.
3
Use the cursor to hover over the an individual PSU subgraphic and a
corresponding text hint or screen tip is displayed. The text hint provides
additional information on that PSU.
4
The PSU subgraphic is hyperlinked to the corresponding CMC GUI page
to provide immediate navigation to the
Power Supply Status
page for all
PSUs.
To view the health status of the PSUs using Power Supply Status:
1
Log in to the CMC Web interface.
2
Select
Power Supplies
in the system tree. The
Power Supply Status
page
displays.
Table 8-6 provides descriptions of the information provided on the
Power
Supply Status
page.
Table 8-6. Power Supply Health Status Information
Item Description
Present Indicates whether the PSU is Present or Absent.
Health OK Indicates that the PSU is present and
communicating with the CMC. In the event of
a communication failure between the CMC
and the power supply, the CMC cannot obtain
or display health status for the PSU.
Warning Indicates that only Warning alerts have been
issued, and corrective action must be taken
within the time frame set by the administrator.
If corrective actions are not taken within the
administrator-specified time, it could lead to
critical or severe power failures that can affect
the integrity of the chassis.