256 Power Management
5
Select one of the following
Power Control Operations
by clicking its radio
button:
Power On Server
— Turns on the server power (equivalent to pressing
the power button when the server power is off). This option is disabled
if the server is already powered on.
Power Off Server
— Turns off the server power (equivalent to pressing
the power button when the server power is on).
Graceful Shutdown
— Powers off and then reboots the server.
Reset Server (warm boot)
— Reboots the server without powering off.
This option is disabled if the server is powered off.
Power Cycle Server (cold boot)
— Powers off and then reboots the
server. This option is disabled if the server is powered off.
6
Click
Apply
. A dialog box appears requesting confirmation.
7
Click
OK
to perform the power management action (for example, cause
the server to reset).
NOTE: All of the power control operations can be performed on multiple servers
from the Servers->Power Management->Control page.
Using RACADM
Open a serial/Telnet/SSH text console to the CMC, log in, and type:
racadm serveraction -m <module> <action>
where <module> specifies the server by its slot number (server-1 through
server-16) in the chassis, and <action> indicates the operation you want to
execute: powerup, powerdown, powercycle, graceshutdown, or
hardreset.
Troubleshooting
For power supply and power-related issue troubleshooting, see
"Troubleshooting and Recovery" on page 297.