User's Manual
256 Power Management
5
Select one of the following
Power Control Operations
by clicking its radio
button:
•
Power On Server
— Turns on the server power (equivalent to pressing
the power button when the server power is off). This option is disabled
if the server is already powered on.
•
Power Off Server
— Turns off the server power (equivalent to pressing
the power button when the server power is on).
•
Graceful Shutdown
— Powers off and then reboots the server.
•
Reset Server (warm boot)
— Reboots the server without powering off.
This option is disabled if the server is powered off.
•
Power Cycle Server (cold boot)
— Powers off and then reboots the
server. This option is disabled if the server is powered off.
6
Click
Apply
. A dialog box appears requesting confirmation.
7
Click
OK
to perform the power management action (for example, cause
the server to reset).
NOTE: All of the power control operations can be performed on multiple servers
from the Servers->Power Management->Control page.
Using RACADM
Open a serial/Telnet/SSH text console to the CMC, log in, and type:
racadm serveraction -m <module> <action>
where <module> specifies the server by its slot number (server-1 through
server-16) in the chassis, and <action> indicates the operation you want to
execute: powerup, powerdown, powercycle, graceshutdown, or
hardreset.
Troubleshooting
For power supply and power-related issue troubleshooting, see
"Troubleshooting and Recovery" on page 297.