User's Manual

I/O Fabric Management 293
Warning Indicates that warning alerts have been issued,
and corrective action must be taken. If
corrective actions are not taken, it could lead
to critical or severe failures that can affect the
integrity of the IOM.
Examples of conditions causing Warnings:
IOM fabric mismatch with the server's
mezzanine card fabric; invalid IOM
configuration, where the newly installed IOM
does not match the existing IOM on the same
group.
Severe Indicates at least one Failure alert has been
issued. Severe status represents a system
failure on the IOM, and corrective action must
be taken immediately.
Examples of conditions causing Severe status:
Failure in IOM detected; IOM was removed.
NOTE: Any change in health is logged to both the hardware and CMC
log. For information on viewing logs, see "Viewing the Hardware Log"
on page 315 and "Viewing the CMC Log" on page 317.
Power Status Indicates the power status of the IOM: On, Off, or N/A (Absent).
Service Tag Displays the service tag for the IOM. The service tag is a unique
identifier provided by Dell for support and maintenance.
Fabric Indicates the type of fabric for the IOM: Gigabit Ethernet, 10GE
XAUI, 10GE KR, 10GE XAUI KR, FC 4 Gbps, FC 8 Gbps, SAS 3
Gbps, SAS 6 Gbps, Infiniband SDR, Infiniband DDR, Infiniband
QDR, PCIe Bypass Generation 1, PCIe Bypass Generation 2.
NOTE: Knowing the fabric types of the IOMs in your chassis is critical
in preventing IOM mismatches within the same group. For information
about I/O fabric, see "I/O Fabric Management" on page 285.
MAC Address Displays the MAC address for the IOM. The MAC address is a
unique address assigned to a device by the hardware vendor as a
means for identification.
NOTE: Pass-throughs do not have MAC addresses. Only switches
have MAC addresses.
Table 10-2. I/O Module Health Status Information (continued)
Item Description