User's Manual

312 Troubleshooting and Recovery
Using RACADM
1
Open a serial/Telnet/SSH text console to the CMC and log in.
2
To view chassis and CMC summaries, type:
racadm getsysinfo
Part Number
Displays the part number for the iKVM. The part number is a
unique identifier provided by the vendor. Part number
naming conventions differ from vendor to vendor.
Firmware Version
Indicates the firmware version of the iKVM.
Hardware Version
Indicates the hardware version of the iKVM.
Power Status
Indicates the power status of the iKVM: On, Off, N/A
(Absent).
Front Panel
USB/Video Enabled
Indicates whether the front panel VGA and USB connectors
are enabled (Yes or No).
Allow Access to CMC
CLI from iKVM
Indicates that CLI access is enabled on the iKVM (Yes or
No).
Table 11-6. IOM Summary
Item Description
Location
Indicates the slot occupied by the IOMs. Six slots are
identified by group name (A, B, or C) and slot number
(1 or 2). Slot names: A-1, A-2, B-1, B-2, C-1, or C-2.
Present
Indicates whether the IOM is present (Ye s or No).
Name
Displays the name of the IOM.
Fabric
Displays the type of fabric.
Power Status
Indicates the power status of the IOM: On, Off, or N/A
(Absent).
Service Tag
Displays the service tag of the IOM. The service tag a unique
identifier provided by the manufacturer for support and
maintenance.
Table 11-5. iKVM Summary (continued)
Item Description