Reference Guide

disableperc
Description
Indicates the RAID configuration of hardware RAID connected to the system. This
subcommand disables the power to a RAID card.
NOTE:
Using this subcommand will power cycle the chassis and set the fault-tolerant
system configuration to Single PERC mode.
Synopsis
racadm raid disableperc:<AdapterFQDD>
Example
racadm raid disableperc:RAID.ChassisIntegrated.2-1
remoteimage
Description Connects, disconnects, or deploys a media file on a remote server.
To use this subcommand, you must have the Administrator privilege.
Synopsis
racadm remoteimage <options>
Input
-c - Connect the image.
-d - Disconnect the image.
-u - Username to access the network share.
-p - Password to access the network share.
-l - Image location on the network share; use double quotation marks
with a location.
-s - Display current status; –a is assumed, if not specified.
Example
racadm remoteimage -c -u "user" -p "pass" -l //shrloc/
foo.iso
Remote Image is now Configured
racadm remoteimage -d - disconnect
Disable Remote File Started. Please check status using -s option to know
Remote File Share is ENABLED or DISABLED.
racadm remoteimage -s - status
Remote File Share is Enabled
UserName
Password
ShareName //192.168.0.1/xxxx/dtk_3.3_73_Linux.iso
serveraction
Description Enables you to perform power management operations on the host system.
95