CLI Guide

Example
racadm getconfig -g cfgTraps -i 2
# cfgTrapsIndex=2
cfgTrapsEnable=1
cfgTrapsAlertDestIpAddr=
cfgTrapsCommunityName=public
cfgTrapsSNMPv3UserId (Read Only)
Table 164. Details of cfgTrapsSNMPv3UserId attribute
Description
Displays the SNMP user ID of an existing CMC user.
Legal Values
1-16
Default
Empty
cfgTrapsSNMPv3UserName
Table 165. Details of cfgTrapsSNMPv3UserName attribute
Description
Congure SNMPv3 user name.
Legal Values
Any existing CMC user name.
Default
Empty
cfgRacTuning
This group is used to congure various iDRAC or CMC conguration properties, such as valid ports and security port restrictions.
Use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have Chassis Conguration Administrator privilege.
Use the -m option to apply this setting to iDRAC.
The following sections provide information about the objects in the cfgRacTuning group.
cfgRacTuneSMBVersionEnable
Table 166. Details of cfgUseCMCDNSSettings attribute
Description
Can be used for setting the SMB version.
Legal Values
SMBv1
SMBv2
114 CMC Property Database Group and Object Descriptions