CLI Guide

cfgRacTuneChassisNameInPromptEnable
Table 188. Details of cfgRacTuneChassisNameInPromptEnable attribute
Description Enables or disables display of the chassis name in the SSH prompt.
Legal Values
0—Disable
1—Enable
Default 0
NOTE: You must have the chassis conguration administrator privilege to set and get the
cfgRacTuneChassisNameInPromptEnable attribute.
cfgServerInfo
For CMC, this group allows you to displays information for and congure a server in the chassis.
For iDRAC this group allows you to select the BIOS rst boot device and provides the option to boot the selected device only once.
Use this object with the cong or getcong subcommands.
To use this object property for CMC, you must have Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgServerInfo group.
cfgServerInfoIndex (Read Only)
Table 189. Details of cfgServerInfoIndex
Description Displays the index name of the server.
cfgServerSlotNumber (Read Only)
Table 190. Details of cfgServerSlotNumber
Description Species the location of the specied server (1–4) in the chassis.
cfgServerServiceTag (Read Only)
Table 191. Details of cfgServerServiceTag
Description Displays the service tag of the specied server.
122 CMC Property Database Group and Object Descriptions