CLI Guide

Table 260. Example
Role Group Privilege Bit Mask
Login to iDRAC 0x00000001
Congure iDRAC 0x00000002
Congure Users 0x00000004
Clear Logs 0x00000008
Execute Server Control Commands 0x00000010
Access Virtual Console 0x00000020
Access Virtual Media 0x00000040
Test Alerts 0x00000080
Execute Debug Commands 0x00000100
cfgChassisPower
This group is applicable only to CMC and contains parameters to display or congure power for the chassis.
Use this object with the cong or getcong subcommands.
To use this object property, you must have the Chassis Conguration Administrator privilege.
The following sections provide information about the objects in the cfgChassisPower group.
NOTE
: While conguring chassis power from a le, update the value for one chassis power cap property and remove the values
for the other chassis power cap properties or, update the last percentage value as it is applicable to all chassis power cap
properties. The chassis power cap properties are: cfgChassisPowerCap, cfgChassisPowerCapF,
cfgChassisPowerCapBTU, cfgChassisPowerCapFBTU, cfgChassisPowerCapPercent, and
cfgChassisPowerCapFPercent.
cfgChassisInPower (Read Only)
Table 261. Details of cfgChassisInPower
Description Indicates the cumulative input power consumption data (in Watts and BTU/hr) captured from all
healthy and functional PSUs in the chassis.
Legal Values None
Default None