cfgChassisPowerCapPercent (Read/Write)
Table 276. Details of cfgChassisPowerCapPercent
Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as
the minimum power + (percent * (maximum power - minimum power)). The command generates an
error if server throttling is necessary to achieve the power goal based on the value for this setting.
Legal Values 16 - 100
NOTE: If the specied percent is lower than the minimum value, the CMC will set the value
to the minimum value.
Default 100
cfgChassisPowerCapFPercent (Read/Write)
Table 277. Details of cfgChassisPowerCapFPercent
Description Indicates the power consumption limit as a percentage. The percentage is computed mathematically as
the minimum power + (percent * (maximum power - minimum power)). Use
cfgChassisPowerCapFPercent when power consumption is to be changed regardless of whether
server throttling is required.
Legal Values 16 - 100
NOTE: If the specied percent is lower than the minimum value, the CMC will set the value
to the minimum value.
Default 100
cfgChassisRedundancyPolicy (Read/Write)
Table 278. Details of cfgChassisRedundancyPolicy
Description Sets the redundancy policy of the chassis.
Legal Values
0 — No redundancy
1 — Grid redundancy
3 — Redundancy alerting only
4 — Fault tolerant redundancy
Default 3 — Redundancy alerting only