CLI Guide
cfgChassisPowerButtonEnable (Read/Write)
Table 283. Details of cfgChassisPowerButtonEnable
Description Indicates if the chassis power button is enabled or disabled.
Legal Values
• 0 (disabled)
• 1 (enabled)
Default None
cfgChassisPowerCapBTU (Read/Write)
Table 284. Details of cfgChassisPowerCapBTU
Description Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. The command
generates an error if server throttling is necessary to achieve the power goal based on the value for
this setting.
Legal Values 9264 - 56931 BTU/hr
Default 43221 BTU/hr
cfgChassisACPowerRecoveryDisable
Table 285. Details of cfgChassisACPowerRecoveryDisable attribute
Description
If AC power recovery is disabled, the chassis is powered o after power outage is restored.
Legal Values
• 0 — Enable
• 1 — Disable
Default
0
cfgKVMInfo
This group is used to view the mapping information for the KVM.
Use this object with the cong or getcong subcommands.
To use this object property, you must have Chassis Conguration Administrator privilege.
CMC Property Database Group and Object Descriptions
149