CLI Guide

Table 30. getdcinfo
<Server#> <Presence> <DC1 Model Name> <DC2 Model Name>
server-1 Present None None
server-2 Not Present None None
server-3 Not Present None None
server-4 Present None Broadcom M5708t
getsleduplinkstatus
Table 31. Details of getsleduplinkstatus
Description
Displays multi-node sled network switch uplink status.
Synopsis
racadm getsleduplinkstatus
Examples
racadm getsleduplinkstatus
Sled No : 2
Port No = 3
A1 Link Status = Up
A2 Link Status = Down
Port No = 4
A1 Link Status = Up
A2 Link Status = Up
Sled No : 3
Port No = 5
A1 Link Status = Up
A2 Link Status = Down
Port No = 4
A1 Link Status = Up
A2 Link Status = Up
getexaddr
Table 32. Details of
getexaddr
Description Displays enabled or disabled status for the entire chassis. If used with -i, the command displays
MACs/WWN on a per-slot–basis.
The decoder values in the Type column indicate the protocols of the network cards:
0— Unsupported
1— ISCSI
2— FCoE-FIP
3— iSCSI/FCoE-FIP
To use this subcommand, you must have CMC Login User privilege.
RACADM Subcommand Details 37