CLI Guide

Table 49. console assigned MAC/WWN of all LOMs or mezzanine cards
<Name> <Type> <Presence> <Active WWN/
MAC>>
<Partition
Status>>
<Assignment
Type>>
CMC N/A Present 34:17:EB:E6:E0:2
4
N/A Factory
Server-1-A 10 GbE KR Not
Installed
10:98:36:AC:
70:EB
Not Installed Not Installed
Server-2 Not Installed Not Present Not Installed Not Installed Not Installed
Server-3-A Reserved Present
Switch-4 Not Installed Not Present Not Installed Not Installed Not Installed
Switch-1 Not Installed Not Present Not Installed N/A N/A
NOTE: If the I/O Modules in slots 1 and 2 are absent and the getmacaddress -a and getmacaddress —c all commands
are run, the output is displayed as Not Installed in the following columns:
<Presence>
<NIC1 MAC Address>
<NIC2 MAC Address>
getmodinfo
Table 50. Details of getmodinfo
Description
Displays conguration and status information for all modules or a specied module (server, storage sled, switch, CMC,
fan unit, blower, power supply unit, chassis, main-board, IO cable, and FPC cable) in the chassis.
To use this subcommand, you must have CMC Login User privilege.
NOTE: The Service Tag eld is blank for modules that do not have Service
Tags.
Synopsis
racadm getmodinfo [-m <module>] [-A]ra
Input
-m < module > — Species the module for which the conguration and status information is required. The
default command (no options) displays information about all the major components in the chassis.
<module > can be one of the following values:
server-n , where n = 1 to 4
server-nx , where n = 1 to 4; x = a to d
switch-n , where n = 1 or 2
pcie-n , where n = 1 to 8
CMC-n , where n = 1
fan-n , where n = 1 to 8
ps-n , where n = 1 to 2
chassis
main-board
io-cable
fpc cable
RACADM Subcommand Details 45