CLI Guide

Default
For iDRAC: 0
For CMC: 1
cfgNicVLanEnable - Read or Write
Table 117. Details of cfgNicVLanEnable
Description Enables or disables the VLAN capabilities.
All chassis management trac, including the CMC and all iDRACs, resides on this external VLAN
when enabled. No iDRAC conguration change is required to use this external management network
VLAN.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
Example
racadm config -g cfgLanNetworking -o cfgNicVLanEnable 1
racadm config -g cfgLanNetworking -o cfgNicVLanEnable 0
cfgNicVLanId - Read or Write
Table 118. Details of cfgNicVLanId
Description Species the VLAN ID for the network VLAN conguration in CMC. This property is only valid if
cfgNicVLanEnable is set to 1(enabled).
Legal Values 1 – 4000 and 4021 – 4094
Default 1
Example
racadm config -g cfgLanNetworking -o cfgNicVlanID 1
cfgNicVLanPriority - Read or Write
Table 119. Details of cfgNicVLanPriority
Description Species the VLAN Priority for the network VLAN conguration in CMC. This property is only valid if
cfgNicVLanEnable is set to 1 (enabled).
Legal Values 0 – 7
Default 0
Example
racadm config -g cfgLanNetworking -o
CMC Property Database Group and Object Descriptions 97