CLI Guide
Default
• For iDRAC: 0
• For CMC: 1
cfgNicVLanEnable - Read or Write
Table 117. Details of cfgNicVLanEnable
Description Enables or disables the VLAN capabilities.
All chassis management trac, including the CMC and all iDRACs, resides on this external VLAN
when enabled. No iDRAC conguration change is required to use this external management network
VLAN.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default 0
Example
• racadm config -g cfgLanNetworking -o cfgNicVLanEnable 1
• racadm config -g cfgLanNetworking -o cfgNicVLanEnable 0
cfgNicVLanId - Read or Write
Table 118. Details of cfgNicVLanId
Description Species the VLAN ID for the network VLAN conguration in CMC. This property is only valid if
cfgNicVLanEnable is set to 1(enabled).
Legal Values 1 – 4000 and 4021 – 4094
Default 1
Example
racadm config -g cfgLanNetworking -o cfgNicVlanID 1
cfgNicVLanPriority - Read or Write
Table 119. Details of cfgNicVLanPriority
Description Species the VLAN Priority for the network VLAN conguration in CMC. This property is only valid if
cfgNicVLanEnable is set to 1 (enabled).
Legal Values 0 – 7
Default 0
Example
racadm config -g cfgLanNetworking -o
CMC Property Database Group and Object Descriptions 97