CLI Guide

Table 28. Details of getdcinfo (continued)
NOTE: Fabric verification for server DCs is performed only when the chassis is turned
on. When the chassis is on stand-by power, iDRACs on the server modules remain
turned off and thus are unable to report the server's DC fabric type. The DC fabric
type may not be reported in the CMC user interface until iDRAC on the server is
turned on.
Synopsis
racadm getdcinfo
Input -n — Displays the model names for the daughter cards in servers.
Table 29. Example
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
Table 30. Server- state
<Server#> <Presence> <DC1 Type> <DC1 State> <DC2 Type> <DC2 State>
server-1 Present PCIe OK PCIe OK
server-2 Not Present None N/A None N/A
server-3 Present PCIe OK None N/A
server-4 Not Present None N/A None N/A
Table 31. getdcinfo
<Server#> <Presence> <DC1 Model Name> <DC2 Model Name>
server-1 Present None None
server-2 Not Present None None
server-3 Not Present None None
server-4 Present None Broadcom M5708t
38 RACADM Subcommand Details