CLI Guide

Static Subnet Mask = 255.255.255.0
Static Gateway = 192.168.0.1
Current IP Address = 10.94.225.212
Current Subnet Mask = 255.255.255.128
Current Gateway = 10.94.225.129
IPv6 Enabled = 0
Autoconfiguration Enabled = 1
Static IPv6 Address = ::/64
Static IPv6 Gateway = ::
Link Local Address = ::
Current IPv6 Address 1 = ::
Current IPv6 Gateway = ::
Speed = Autonegotiate
Duplex = Autonegotiate
VLAN Enable = 0
VLAN ID = 1
VLAN priority = 0
$
$ racadm getniccfg -m server-3
LOM Model Name = BRCM GbE 4P 5720 bNDC
LOM Fabric Type = Gigabit Ethernet
IPv4 Enabled = 1
DHCP Enabled = 0
IP Address = 0.0.0.0
Subnet Mask = 0.0.0.0
Gateway = 0.0.0.0
IPv6 Enabled = 0
Autoconfiguration Enabled = 1
Link local Address =
IPv6 Gateway = ::
VLAN Enable = 0
VLAN ID = 1
VLAN priority = 0
getpbinfo
Table 54. Details of getpbinfo
Description Displays power budget status information.
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getpbinfo
Example
racadm getpbinfo
[Power Budget Status]
System Input Power = 90 W
Peak System Power = 93 W
Peak System Power Timestamp = 20:28:32 03/04/2014
Minimum System Power = 83 W
Minimum System Power Timestamp = 20:28:02 03/04/2014
Overall Power Health = OK
Redundancy = Yes
System Input Power Cap = 3371 W
Redundancy Policy = Redundancy Alerting Only
System Input Max Power Capacity = 2382 W
Input Redundancy Reserve = 0 W
Max Power Conservation Mode = 11:20:08 02/27/2014
Power Available for Server Power-on = 1965 W
[Chassis Power Supply Status Table]
<name> <Model> <Power State> <Input Current> <Input Volts> <Output Rated Power>
RACADM Subcommand Details
53