CLI Guide

Table 89. Details of setassettag (continued)
To use this subcommand, you must have the Administrator privilege.
NOTE: The special characters " (double quote), ` (back quote), & (ampersand), and \
(backslash) are not supported for this subcommand.
Synopsis
racadm setassettag -m chassis <asset tag>
Input -m < module > — Specifies the module whose asset tag you want to set.
Legal value: chassis
You can obtain the same output if you do not include this option, because there is only one legal
value.
< assettag > is a maximum of 64 non-extended ASCII characters.
Example
racadm setassettag -m chassis 783839–33
racadm setassettag 783839–33
The asset tag was changed successfully.
setchassisname
Table 90. Details of setchassisname
Description Sets the name of the chassis.
To use this subcommand, you must have the Administrator privilege.
NOTE: The special characters " (double quote), ` (back quote), & (ampersand), >
(greater than), < (less than), and \ (backslash) are not supported for this
subcommand.
Synopsis
racadm setchassisname <name>
NOTE: Chassis name is a maximum of 64 unextended ASCII characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.
setflexaddr
Table 91. Details of setflexaddr
Description Enables or disables FlexAddress on a particular slot or fabric.
To use this subcommand, you must have the Chassis Configuration Administrator privilege.
If the fabric type is determined to be Infiniband, the operation is canceled and the command returns an
error. If the FlexAddress feature is not activated, the command returns an error.
RACADM Subcommand Details 85