Release Notes
Known Issues
• Issue 1:
Description
XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device page and OS.
Resolution
Virtual reseat or Physical reseat of the server
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX and PowerEdge servers with iDRAC7 or earlier.
• Issue 2:
Description
After Shared PERC8 controller update, RAID-related operations may take longer to report status.
Resolution
Wait for the operation status to report.
Versions/Systems Aected
CMC version 2.01 or later for Dell PowerEdge VRTX.
• Issue 3:
Description
An error occurs while importing CMC conguration le using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the command, “racadm
cong -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Aected
CMC Version 2.0 or later for Dell PowerEdge VRTX
• Issue 4:
Description
At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert, “Foreign Conguration was
detected on Physical Disk”.
Resolution
None. The alert is not displayed only at times. But, the functionality for foreign conguration is not aected.
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX
8