Release Notes

Known Issues
Issue 1:
Description
XWKGY_Intel10G card shows Flex disabled address after racresetcfg of CMC in Network Device page and OS.
Resolution
Virtual reseat or Physical reseat of the server
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX and PowerEdge servers with iDRAC7 or earlier.
Issue 2:
Description
After Shared PERC8 controller update, RAID-related operations may take longer to report status.
Resolution
Wait for the operation status to report.
Versions/Systems Aected
CMC version 2.01 or later for Dell PowerEdge VRTX.
Issue 3:
Description
An error occurs while importing CMC conguration le using local racadm or remote racadm.
Resolution
This issue occurs when IPv6 is enabled or disabled from the conguration le. Enable or disable IPv6 using the command, “racadm
cong -g cfgIPv6LanNetworking -o cfgIPv6Enable 0”.
Versions/Systems Aected
CMC Version 2.0 or later for Dell PowerEdge VRTX
Issue 4:
Description
At times when foreign drives are inserted, the Chassis Overview Health tab does not display the alert, “Foreign Conguration was
detected on Physical Disk.
Resolution
None. The alert is not displayed only at times. But, the functionality for foreign conguration is not aected.
Versions/Systems Aected
All CMC versions including CMC 3.00 for Dell PowerEdge VRTX
8